[Take a look at the causes and solutions of water chiller leaks!]
Release date:[2022/12/2] Is reading[435]次

Take a look at the causes and solutions of water chiller leakage, it is recommended to save.

The water -cooled screw chiller of the chiller is composed of the inlet pipe, the evaporator, the outlet pipe, the water tank, the chilled water pump, the cooling water pump, the condenser, and the pipes and valves at the connection. The above parts are basically necessary for the water leakage failure. The following is the solution to the water leakage of the chiller.

Water -cooled screw chiller and outlet leakage, generally is the connection bolt loose or broken water leakage, repair or replacement can be done; The floating ball valve of the water -cooled screw chiller is leaking. The floating ball valve controls the inlet valve switch according to buoyancy. The solution is to check and adjust the position of the ball valve.

If the evaporator shell of the water -cooled screw chiller is leaking, it is necessary to check whether there is water seepage at the welding place of the evaporator shell. If so, it should be repaired by welding as soon as possible. Water leakage occurs in the condenser perforation inside the chiller. The solution is to find the fault point and repair it; The water in the water tank of the water -cooled screw chiller is too full to cause the cooling water to fluctuate and leak during operation. The solution is to reduce the water level in the water tank; If the water tank of the chiller leaks, trachoma may appear in the welding position of the water tank or be used for a long time. The solution is to pull it back to the manufacturer to re-weld the leaking position; The water pump of the water chiller leaks. The cause may be that the shaft seal at the water pump is not well connected or the shaft seal has been damaged. The solution is not to change the shaft seal and directly change the pump. If the cold water tilts for a long time, the pressure on the chiller's valves and pipes will be uneven and damaged, causing water leakage. The chiller should be placed horizontally according to the specifications. If the water chiller leaks, it should follow the water trace to find the water leakage point of the unit. If the water leakage of the water chiller occurs on the water cooling system, it will cause insufficient water flow, compressor high pressure alarm and other failures. If the water leakage is not handled in time, it will also cause water at the bottom of the water chiller, corrosion of the unit shell, and potential safety hazards to the electrical parts of the unit. So once found water chiller leakage phenomenon, should pay attention to, timely maintenance.

If you can't find the reason, you should turn to the chiller manufacturer for help, find professional after-sales personnel for consultation, operate under the guidance of professional after-sales personnel, and maintenance must not be carried out blindly.